Mac-Mod Avantor ACE Excel Advanced MDK, (C18, C18-AR, C18-PFP), 100 Å, 5 µm, 4.6 x 150 mm
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
All Avantor ACE UHPLC and HPLC Method Development Kits are comprised of analytical columns with different bonded phases, specially priced at the list price of 1 column to ensure that chromatographers can evaluate different bonded phase chemistries that provide alternative selectivity during the method development stage of their analytical projects. Evaluate all 5 ACE Method Development kits to explore the selectivity space (Advanced, Extended, UltraCore, HILIC and Bioanalytical). All Avantor ACE Method Development kits are tested to meet the stringent internal quality standards. The columns selected for each kit are designed to leverage different modes of interaction (pi-pi, dipole-dipole, hydrophobic, hydrogen bonding, or shape selectivity). All columns in the kit are the same column ID, column length and particle size. NOTE: Avantor ACE Method Development Kits cannot have any special lot or batch requests.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Symmetry Method Validation Kit, C18, 5 μm, 4.6 mm X 250 mm
This kit consists of three C18 columns packed with different batches of sorbent, ensuring unparalleled reproducibility. It uses high purity base-deactivated silica and a monofunctional bound C18 ligand, resulting in consistent batch-to-batch results and reduced variations in resolution.
- Utilizes high purity base-deactivated silica and a monofunctional bound C18 ligand.
- Ensures unparalleled reproducibility and consistent batch-to-batch results.
- Adheres to the industry’s tightest ligand surface coverage standards.
- Saves labor by eliminating constant method validation.
- Manufactured with high-purity raw materials for repeatable HPLC columns.
- Includes a three-page Certificate of Analysis detailing specifications and 22 quality tests.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Vent Valve Cartridge Assembly, Tubing, UPLC System
This vent valve cartridge assembly serves as a replacement component for various UPLC systems and solvent managers.
- Replacement vent valve cartridge assembly
- Designed for UPLC system applications
- Compatible with ACQUITY I-Class Binary Solvent Managers
- Compatible with ACQUITY Isocratic Solvent Manager
- Compatible with PATROL Sample Manager
- Compatible with ACQUITY UPLC I-Class System
- Compatible with ACQUITY UPLC ISM
- Compatible with ACQUITY UPLC BSM
- Compatible with ACQUITY UPLC Process Sample Manager
- Supplied as 1 unit per package
- Features tubing type construction
- Replaced as required for optimal performance
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp CORTECS HILIC Method Validation Kit, 90Å, 1.6 μm, 2.1 mm x 50 mm, 3/pk
The CORTECS HILIC Method Validation Kit is designed for method validation in HILIC chromatography. It includes columns suitable for analytical applications.
- 90Å pore size
- 1.6 μm particle size
- 2.1 mm x 50 mm column dimensions
- Contains 3 columns
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Method Validation Kit, BioResolve Polyphenyl, 450Å, 2.7 μm
The BioResolve RP mAb Method Validation Kit offers three columns with 2.7μm superficially-porous-silica particles and 450Å pore diameter. Ideal for LC or LC-MS analyses of intact IgG monoclonal antibodies and fragments, the kit includes columns from different batches, along with Intact mAb Mass Check Standard and mAb Subunit Standard for performance benchmarking, ensuring robust performance.
- Separation mode: Reversed Phase
- Particle size: 2.7 μm
- Pore size: 450 Å
- Column kits
- 3 units per package
- Column dimensions: 4.6 mm × 100 mm
- Superficially-porous silica particle composition
- Proprietary polyphenyl bonding process
- Application for LC or LC-MS analysis of intact IgG monoclonal antibodies and fragments
- Included standards: Intact mAb Mass Check Standard and mAb Subunit Standard
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corporation Glycan Performance Test Standard, N-Glycan, RapiFluor-MS, 400 pmoles
This RapiFluor-MS Glycan Performance Test Standard is a benchmarking standard and labeled, complex control for N-Glycan analysis. It contains N-glycan content from 30 μg of human IgG, providing approximately 400 pmoles of RapiFluor-MS labeled, released N-glycans.
- Functions as a benchmarking standard and labeled control.
- Contains N-glycan content from 30 μg of human IgG, approx. 400 pmoles of RapiFluor-MS labeled, released N-glycans.
- Maximizes information from ms detection.
- Streamlines deglycosylation and labeling.
- Balances speed and sensitivity for confident analytical results.
- High sensitivity mass detection for flr and ms.
- Reduces chromatography analysis times.
- Integrates with gmp-compliant uplc workflows.
- Storage: –20°C upon arrival; –80°C (up to 3 months) or 4–10°C (up to one week) once solubilized.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp CORTECS Method Validation Kit, Phenyl, 2.7 μm, 90 Å
Method validation kits provide columns of three different batches. Phenyl columns offer complementary selectivity to C18 stationary phases. The particle morphology delivers high efficiency and lower backpressures compared to fully porous particles of similar size. These columns provide ultra-low column MS bleed, long lifetimes, and excellent peak shape.
- Phenyl chemistry for reversed phase separation.
- Silica particle substrate.
- pH range of 2 to 8.
- Maximum pressure of 18000 psi (1240 Bar).
- Particle size of 2.7 μm.
- Pore size of 90 Å.
- Inner diameter of 2.1 mm.
- Length of 30 mm.
- Includes 3 units per package.
- Compatible with UPLC and UHPLC systems.
- Solid core particle technology.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp BioResolve SCX mAb Method Validation Kit with VanGuard FIT, 3 µm, 2.1 mm x 100 mm, 3/pk with mAb Charge Variant Standard
BioResolve SCX mAb Method Validation Kit with VanGuard FIT, 3 µm, 2.1 mm x 100 mm, 3/pk with mAb Charge Variant Standard
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Isolator Column, Reversed Phase, Hybrid, 2.1 mm ID, 50 mm Length
Designed to be used with ACQUITY Application Specific Kits, the Isolator Column separates background contaminates from the sample to be analyzed, thus removing interferences and allowing for extremely low detection limits. It is utilized for applications such as Perfluorinated Compounds (PFCs/PFOA/PFOS) and Bisphenol A.
- Separation mode: Reversed Phase.
- Particle substrate: Hybrid.
- pH range: 1 to 12.
- Endcapped: Yes.
- Silanol activity: Low.
- Particle shape: Spherical.
- Endfitting type: Parker-style.
- System compatibility: UPLC, UHPLC.
- Inner diameter: 2.1 mm.
- Length: 50 mm.
- Units per package: 1 pk.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp CORTECS HILIC Method Validation Kit, 90à , 1.6 µm, 3 mm X 150 mm, 3/pk
CORTECS HILIC Method Validation Kit, 90à , 1.6 µm, 3 mm X 150 mm, 3/pk
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Neta Scientific CAPILLARY 0.12 MM ID 500 MM
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This item is manufactured by Agilent
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Waters Sample Manager Performance Maintenance Kit, nanoACQUITY, Annual, 5000/10000 psi Systems
This kit contains all the necessary parts to keep the sample manager operating at peak performance annually. It is designed to fit into both 5000 psi and 10,000 psi nanoACQUITY systems.
- Air chassis filter
- Injector outlet tubes
- Needle
- System outlet tubes
- Inject valve pod
- Wash syringe
- Injector syringe
- Sample loop
- O-ring
- Vent valve cartridge
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Atlantis T3 Column, C18, 5 μm, 4.6 mm × 150 mm
The Atlantis T3 Column is a C18 reversed-phase column built on a spherical silica particle substrate. It features a 100 Å pore size, 5 μm particle size, and dimensions of 4.6 mm × 150 mm. This column is designed with T3 bonding technology and can withstand a maximum pressure of 6000 psi (415 Bar). It includes an eConnect Column Tag for automatic identification, tracking, and digital tracing of column usage.
- Equipped with an electronic eConnect column tag for unique, traceable column-specific information.
- NFC-enabled design allows automatic identification, tracking, and digital tracing of column use history.
- Compatible with any HPLC, with enhanced features on compatible iS systems running Empower software.
- Features C18 chemistry, spherical silica particles, and T3 bonding technology.
- Withstands maximum pressure of 6000 psi (415 Bar) and offers a pH range of 2 to 8.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Thermo Scientific Viper Fingertight Fitting Systems | PEEK | 1 EA
Ferrule-free tightening design for virtually zero-dead-volume connections, Operates at pressures up to 345 bar, Fingertight design, Flexible biocompatible PEEK capillaries 1/32 in OD, No tools required, Compatible with virtually any manufacturer valve and column, Fits narrow connections such as 10-port valves, Available in different materials lengths and inner diameters
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp CORTECS HILIC Method Validation Kit, 90à , 1.6 µm, 3 mm X 30 mm, 3/pk
CORTECS HILIC Method Validation Kit, 90à , 1.6 µm, 3 mm X 30 mm, 3/pk
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More